Determination of residual impurities in pharmaceutical excipient cetomacrogol 1000 by gas chromatography

Funds: This study was supported by China National Key Hi-Tech Innovation Project for the R&D of Novel Drugs (No.2017ZX09101001-006-002) and the Drug Standard Establishment and Revision Project of Chinese Pharmacopoeia Commission (No.2020Y047)
More Information
  • Received Date: January 05, 2022
  • Revised Date: May 13, 2022
  • For the quality control of cetomacrogol 1000, a gas chromatographic method for the determination of residual impurities in cetomacrogol 1000, such as ethylene oxide, 1, 4-dioxane, ethylene glycol, diethylene glycol and triethylene glycol, was established and validated.The DB-1 column with headspace injection was used to detect ethylene oxide and 1, 4-dioxane with the inlet temperature of 150 °C, the FID temperature of 250 °C, the headspace equilibration temperature of 70 °C and the equilibration time of 45 min.The VF-17MS column with liquid injection was used to detect ethylene glycol, diethylene glycol and triethylene glycol with the inlet temperature of 270 °C, and the FID temperature of 290 °C.The results showed that ethylene oxide and 1,4-dioxane have a good linearity within their specified addition amount ranges (r > 0.999), with the RSD of precision of below 8.0% and the average recovery rates of 90.6% and 101.2%; and that ethylene glycol, diethylene glycol and triethylene glycol also have a good linearity between 3 ? 60 μg/mL (r > 0.999), with the RSD of precision of below 3.0%, and the recovery rates of 96% ~ 103%.The method established in this study has good specificity, linearity, precision and recovery rate, which can effectively detect the multi-component and trace impurities.
  • [1]
    . ACS Omega,2021,6(32):20975-20983.
    [2]
    Eccleston GM. Structure and rheology of cetomacrogol creams:the influence of alcohol chain length and homologue composition[J]. J Pharm Pharmacol,1977,29(3):157-162.
    [3]
    Secretin L,Anyakudo F,Gilissen L,et al. Qualitative analysis of cetomacrogol creams by thin-layer chromatography-flame ionization detection (TLC-FID)[J]. SN Appl Sci,2020,2(9).doi:https://doi.org/10.1007/s42452-020-03389-4.
    [4]
    Chen L,Zhang Y,Zheng A,et al. Thoughts on the high quality development of pharmaceutical excipients industry in China[J]. Chin Pharm Aff (中国药事),2021,35(9):972-977.
    [5]
    Liu J,Wu Y,Li HL. Determination of ethylene oxide and dioxane in PEG 10000 by headspace gas chromatography[J]. Drug Stand China(中国药品标准),2017,18(2):117-119.
    [6]
    Yi CC,Sha RL,Chen QY,et al. Quality study of pharmaceutical excipient polysorbate 80[J]. J China Pharm Univ(中国药科大学学报),2020,51(2):168-174.
    [7]
    Lei YJ,Xiong YR,Zhu YY,et al. Determination of ethylene glycol,diethylene glycol and triethylene glycol in poloxamer 188 by gas chromatography[J]. J China Pharm Univ(中国药科大学学报),2019,50(6):694-698.
    [8]
    Gao S,Zhu S,Zhao X,et al. Comparative study on HPLC and GC methods for determination of ethylene glycol and diethylene glycol residues in polyethylene oxide[J]. Chin J Pharm Anal (药物分析杂志),2020,40(10):1820-1827.
    [9]
    Duan MR,He DS,Sun HM,et al. Determination of epoxide impurity in Poloxamer188 by gas chromatography[J]. J Pharm Res(药学研究),2020,39(6):331-335,340.
    [10]
    The British Pharmacopoeia Commission. British Pharmacopoeia:Monograph 1123[S]. London:The Stationery Office,2020:1123-1125.
    [11]
    The United States Pharmacopeial Convention. United States Pharmacopoeia:Vol 31(3)[S]. 43th ed. Rockville:The United States Pharmacopeial Convention,2020:5955-5957.
    [12]
    World Health Organization. The International Pharmacopoeia[EB/OL]. 10th ed. https://digicollections.net/phint/2020/index.htmL#p/home.
    [13]
    Chinese Pharmacopoeia Commission. Chinese Pharmacopoeia:part 4(中华人民共和国药典:四部)[S]. Beijing:China Medical Science Press,2020:819-820.
  • Related Articles

    [1]ZHANG Keke, LIN Jinsheng, ZHENG Lewei, WANG Jichao, LI Min, SHEN Weiyang. Structural elucidation and mechanism study for Hofmann-Martius-like rearrangement products in duloxetine hydrochloride under the process condition[J]. Journal of China Pharmaceutical University, 2023, 54(4): 474-482. DOI: 10.11665/j.issn.1000-5048.2023022102
    [2]LIU Xiao-rong, YOU Qi-dong, WANG Jin-xin. Tandem Claisen rearrangement/Diels-Alder reaction in ionic liquid[J]. Journal of China Pharmaceutical University, 2009, 40(6): 481-485.
    [5]By-products from Mannich Reaction of Dihydrobenzopyranones[J]. Journal of China Pharmaceutical University, 1996, (2): 71-73.
    [8]Synthesis of Dihydrobenzopyran-4-Oximes and Oxime Esters[J]. Journal of China Pharmaceutical University, 1995, (3): 129-133.

Catalog

    Article views (263) PDF downloads (362) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return